CALL;
A.WIHARTA
081294124885
085778084789
087784022201
Karya Mandiri Instrument indonesia adalah supplier peralatan laboratorium baik eletronik maupun mekanik, serta berbagai macam instrument measurement, dengan didukung dari berbagai macam merk dari negara negara Eropa, US, dan beberapa negara di Asia seperti Korea, Japan dan Taiwan. Instrument yang kami sediakan seperti : Anemometer, Analitical Balance, Spectrophotometer, pHmeter, Laser survey, Micropipette, Peristaltic Pump, Flame photometer, Water bath heating cooling, Colorimeter, Water Strirer, Viscometer. Freezers, Refractometer, Polarimeter, Sound Level meter, Tachometer. Dll
Kami juga menerima jasa service dan kalibrasi untuk peralatan laboratorium sesuai kemampuan kami.
The New World Standard for Power Quality Analysis, with recording & analyzing The PW3198 can measure all waveforms of power, harmonic, and error events simultaneously. When a problem occurs with the equipment or system on your site, the PW3198 will help you detect the cause of the problem early and solve it quickly. You can depend on the PW3198 to monitor all aspects of your power supplies. The PW3198 can simultaneously record 8, 000 or more parameters, such as voltage, current, power, power factor, frequency, integral power, harmonic, and flicker, at the specified recording interval. The PW3198 never fails to capture the peak because it performs calculations continuously and records the maximum, minimum, and average values within the recording interval. Features: Compliance with the IEC 61000-4-30 Class A international power quality standard and dramatically improved measurement reliability - Compliance with the IEC 61000-4-30 Class A international standard on power quality measurement, which stipulates the most stringent requirements in the field, points to the PW3198’ s unparalleled functionality and reliability. To comply with the standard, the instrument delivers basic voltage measurement precision of 0.1% , an improvement of 200% over the previous model. Simple configuration function for intuitive operation - The PW3198 incorporates a user-friendly configuration function that automatically selects the necessary measurement items once the user has chosen a measurement pattern, for example abnormal voltage detection. This capability eliminates the need for the user to configure a series of complex settings, significantly improving the instrument’ s convenience. Extended measurement capability thanks to flexible use of SD cards ( 2 GB card bundled with product) - The need for continuous monitoring in power quality measurement applications makes extended recording capability a must. The PW3198 ships standard with a 2 GB SD card that allows continuous measurement for up to 55 weeks. Improved safety thanks to CAT IV 600 V compliance - Whereas the PW3198’ s predecessor POWER QUALITY ANALYZER 3196 offered a CAT III 600 V safety level as defined by IEC 61010, the new PW3198 complies with CAT IV 600 V requirements. The higher level of protection enables the instrument to safely measure incoming power lines. Measurement items: Transient overvoltage : 2MHz sampling. Frequency cycle : Calculated as one cycle, 40 to 70Hz RMS voltage/ RMS current refreshed each half-cycle Voltage swell, Voltage dips, Voltage interruption Inrush current Voltage waveform comparison Instantaneous flicker value: As per IEC61000-4-15 Frequency: Calculated as 10 or 12 cycles, 40 to 70Hz 10-sec frequency: Calculated as the whole-cycle time during the specified 10s period, 40 to 70Hz Voltage waveform peak, Current waveform peak Voltage, Current, Active power, Apparent power, Reactive power, Active energy, Reactive energy, Power factor, Displacement power factor, Voltage unbalance factor, Current unbalance factor ( negative-phase, zero-phase) High-order harmonic component ( voltage/ current) : 2kHz to 80kHz Harmonic/ Harmonic phase angle ( voltage/ current) , Harmonic power: 0th to 50th oders Harmonic voltage-current phase angle: 1th to 50th orders Total harmonic distortion factor ( voltage/ current) Inter harmonic ( voltage/ current) : 0.5Hz to 49.5Hz K Factor ( multiplication factor) IEC Flicker, ” V10 Flicker Features: Verify power problems in accordance with the IEC61000-4-30 Class A standard High Accuracy and continuous gapless recording ( V: ± 0.1% of nominal voltage, A and W: ± 0.2% rdg. ± 0.1% f.s.) CAT IV 600V - safe enough for incoming power lines Broadband voltage range lets you measure even high-order harmonic components of up to 80 kHz Wide dynamic range from low voltages up to 1300V ( 3P4W line-to-line voltage) Maximum 6000V transient overvoltage up to 700kHz LAN, USB and SD card interfaces Optional GPS BOX for synchronizing multiple devices