DKI Jakarta - Jakarta Timur

HI 98121 Combo pH/ ORP/ Temperature Tester

Harga :
CALL
Lokasi :
DKI Jakarta - Jakarta Timur
Dilihat :
8 Kali
Update Terakhir :
03-12-2019 06:07

Detail Produk

CALL: A.WIHARTA 081294124885 085778084789 087784022201 Karya Mandiri Instrument indonesia adalah supplier peralatan laboratorium baik eletronik maupun mekanik, serta berbagai macam instrument measurement, dengan didukung dari berbagai macam merk dari negara negara Eropa, US, dan beberapa negara di Asia seperti Korea, Japan dan Taiwan. Instrument yang kami sediakan seperti : Anemometer, Analitical Balance, Spectrophotometer, pHmeter, Laser survey, Micropipette, Peristaltic Pump, Flame photometer, Water bath heating cooling, Colorimeter, Water Strirer, Viscometer. Freezers, Refractometer, Polarimeter, Sound Level meter, Tachometer. Dll Kami juga menerima jasa service dan kalibrasi untuk peralatan laboratorium sesuai kemampuan kami.   Waterproof and it floats! HANNA’ s exclusive cartridge pH and ORP electrode Extendable cloth pH junction Automatic Temperature Compensation Automatic calibration Battery % Level at startup and stability indicator HOLD function HI 98121 is a waterproof meter that measures pH, ORP and temperature. The housing of this tester has been completely sealed against humidity and are designed to float. Electrode replacement with the stainless steel round connector means there are no pins to bend or break during replacement. When the cloth junction becomes clogged and response time is sluggish, simply pull out 3 mm ( 1/ 8” ) to clear the clogging which will improve response time and stability. The exposed stainless steel temperature sensor on these models facilitates faster and more accurate temperature measurement. Order Information: HI 98121 ( ORP/ pH) is supplied with HI 73127 pH electrode, HI 73128 electrode removal tool, batteries and instructions. Range ORP ± 1000 mV pH -2.00 to 16.00 pH Temperature -5.0 to 60.0° C / 23.0 to 140.0° F Resolution ORP 1 mV pH 0.01 pH Temperature 0.1° C / 0.1° F Accuracy ORP ± 2 mV pH ± 0.05 pH Temperature ± 0.5° C / ± 1° F Calibration ORP factory calibrated pH automatic, one or two points with two sets of memorized buffers ( pH 4.01 / 7.01 / 10.01 or 4.01 / 6.86 / 9.18) Temperature Compensation Automatic for pH readings Electrode HI 73127 replaceable pH electrode ( included) ; fixed ORP sensor Battery Type / Life 1.5V ( 4) / approximately 250 hours of continuous use; auto-off after 8 minutes of non-use Environment -5 to 50° C ( 23 to 122° F) ; RH max 100% Dimensions 163 x 40 x 26 mm ( 6.4 x 1.6 x 1.0" ) Weight 100 g ( 3.5 oz.)

Permintaan Penawaran